Providing Innovative & Technologically Advanced Products & Services For The Next Century And Beyond

**

**

 

Specification(s):

   
   

*E* value (Emissive):

0.22   +- 0.01

Reflectivity:

.88

*C* value (conductivity) of heat surface area:

40%     (60% vacuum filled)

Thermal Conductivity:

0.06 - 0.2 W/mK

Temperature Stable:

to 1200 + Degrees F   

Depending on Duration of Exposure

Crush Strength:

400  psi

Appearance & Odor: Low Density:

Fine Powder White, Odorless.,

Specific Gravity: .12 - .63 g/cc 

Effective Top Size:

125 (microns by volume)

Low Viscosity Density:

Minimum.15 to Maximum.17 Per ASTM D2840

Oil Absorption:

31-36 oil/100 cc     Per ASTM D1483

Conductivity Dielectric Constant:

1.2 to 1.7 @ 100 MHZ  

Depending on Composite/Matrix/Volume

Alkalinity:

Maximum of 0.5 Milli equivalents Per Gram

ASTM D3100 (1982 Edition)

Abrasion Resistance Hardness:

Mohs' 7 Hardness

Water Resistant:

Flotation Typical 96% Test Method TM-587

Chemical Stability:

Stable

Unusual Fire & Explosive Hazards:

No Unusual Fire & Explosive are Anticipated

NFPA Hazard Codes:

Health: 0  Fire:  0  Reactivity:  Unusual  Reactivity Hazard: None

 (NFPA = National Fire Protection Association)

   

REACTIVITY DATA

 

STABILITY:

Stable

 INCOMPATIBILITY MATERIALS/CONDITIONS TO AVOID:  None Known.    

HAZARDOUS POLYMERIZATION:

Hazardous Polymerization Will Not Occur.

* E value    Emissivity Reflectance of Radiant Heat.
* C value    Conductivity The Conductance of or heat transfer thru material.

**

**

 

FAQ

Specs.

 

 

 

 

US Dept of Defense

Registered

Trading Partner

 

 

 

 

 

 

 

 

SOME OF OUR LAB EQUIPTMENT USED FOR TESTING
Emissometer

THIS EMISSOMETER IS THE STANDARD TO PERFORM ASTM C 1371 -04a

STANDARD TEST METHOD FOR DETERMINATION OF EMITTANCE OF MATERIALS

NEAR ROOM TEMPERATURE USING PORTABLE EMISSOMETER'S

INSTRUMENT USED BY HEAT ISLAND GROUP

 

Holometrix Thermal Conductivity Instrument

Holometrix Thermal Conductivity Instrument

Holometrix Thermal Conductivity Instrument

THIS HOLOMETRIX CONDUCTIVITY INSTRUMENT IS THE SAME TYPE USED BY:
Benedetta Marmiroli
University of Ferrara
TO PERFORM
Thermal Conductivity Measurement of Nanoparticle Based Solid
Propellant Mixtures FOR
AMTT
European Major Research Infrastructure
Aerospace and Space Materials Technology Testhouse
Contract Number HPRI-CT-1999-00024
ARC Seibersdorf Research GmbH, Austria
PAPERS AVAILABLE ON REQUEST

Holometrix Thermal Conductivity Instrument

Holometrix Thermal Conductivity Instrument